This is a Test site - No orders shall be fulfilled

No Image
Available
Goodman Split Heat Pump 16 SEER, Two Stage
Image may not reflect selected features
Goodman Split Heat Pump 16 SEER, Two Stage (GSZC160241) by Goodman
Goodman GSZC16 Split Heat Pump 16 SEER & 9 HSPF, Two Stage, 2 Ton, ComfortBridge Technology compatible
Product Specification
Item #
GSZC160241
Dimensions
Additional product details
Internal #
3509LT6A
Category
HEAT PUMPS
Market Type
Residential-Single Family
Unit Type
Outdoor
Tonnage
2
SEER
16
Additional Refrigerant Charge Ozft
0.6
Ahri Reference Number
202149334
Air Flow Rate High Cooling
860 ft³/min
Air Flow Rate High Heating
860 ft³/min
Air Flow Rate Low Cooling
500 ft³/min
Air Flow Rate Low Heating
500 ft³/min
Canadian Hts Code
8415.90.90.00
Capacity Control Range Max
23600
Capacity Control Range Min
22400
Case Depth
37.00 in
Case Height
38.50 in
Case Width
37.00 in
Communication Feature
Yes
Communication Feature Type
ComfortBridge Technology compatible
Compressor Lra
62.9 A
Compressor Rla
10.0 A
Compressor Sound Blanket
Yes
Compressor Stages
Two Stage
Compressor Type
Scroll
Condenser Fan Blade Count
3
Condenser Fan Diameter
26 in
Condenser Fan Horsepower
1/5 metric hp
Condenser Fan Rpm
830 r/min
Control Voltage Conduit Size
1/2 in;3/4 in
Cooling Capacity Nominal
23600 Btu/H
Cooling Capacity Rated
23600 Btu/H
Cooling Capacity Sensible
19000 Btu/H
Cooling Operation Range Std Max
115 °F
Cooling Operation Range Std Min
55 °F
Cop17 Ducted
2.6
Cop17 Hsvtc
2.6
Cop47 Ducted
4
Cop47 Hsvtc
4.02
Country of Origin
USA
Current Type
AC
Doe Regional Compliance
North;Southeast;Southwest
Eer Ducted
13
Eer Hsvtc
13
Energy Source
Electric
Energy Star Certified
Yes
ETL Listed
Yes
Expansion Device
TXV
Factory Std Refrigerant Charge
176 oz
Heat Exchanger Type
Air Cooled
Heating Capacity Max
22500 Btu/H
Heating Capacity Min
13600 Btu/H
Heating Capacity Nominal
22200 Btu/H
Heating Operation Range Stdmax
70 °F
Heating Operation Range Stdmin
-20 °F
Hspf Ducted
9
Hspf Hsvtc
9
Indoor Orifice Size
N/A in
Indoor Txv Kit
TX2N4A
Installation Type
Ducted
Long Line Set Length Equivalent
150 ft
Long Line Set Length Linear
150 ft
Max Overcurrent Protection
20 A
Max Voltage
253 V
Min Circuit Amps
13.5 A
Min Voltage
197 V
Model Efficiency
16 SEER
Model Status
Active
Outdoor Fan Fla
1:00 AM
Pipe Size Gas
3/4 in
Pipe Size Liquid
3/8 in
Power Frequency
60 Hz
Power Phase
1 Ph
Power Supply Conduit Size
1/2 in;3/4 in
Power Voltage
208/230 V
Produced in US
Yes
Proposition65 Label
Yes
Rated Cooling Condition Ambient Db
95 °F
Rated Cooling Condition Ambient Wb
75 °F
Rated Cooling Condition Room Db
80 °F
Rated Cooling Condition Room Wb
67 °F
Rated Heating Condition Ambient Db
47 °F
Rated Heating Condition Ambient Wb
43 °F
Rated Heating Condition Room Db
70 °F
Rated Heating Condition Room Wb
60 °F
Rated Load Amps
10:00 AM
Refrigerant Precharged Line Length
15 ft
Refrigerant Type
R-410A
Registered Parts Warranty Commercial
ALL PARTS - 5 YEARS PARTS
Registered Parts Warranty Multifamily
ALL PARTS - 10 YEARS PARTS
Registered Parts Warranty Residential
COMPRESSORS - LIFETIME PARTS;ALL PARTS - 10 YEARS PARTS
Registered Unit Replacement Warranty Residential
COMPRESSORS - 10 YEARS UNIT REPLACEMENT
SEER Ducted
16
Sensible Heat Ratio St
0.81
Series Name
GSZC16
Shipping Unit Depth
37.00 in
Shipping Unit Height
38.50 in
Shipping Unit Volume
52706.500 in³
Shipping Unit Weight
235.000 lb
Shipping Unit Width
37.00 in
Sound Pressure High Cooling
73 dBA
Sound Pressure High Heating
74 dBA
Sound Pressure Low Cooling
71 dBA
Sound Pressure Low Heating
72 dBA
Standard Line Set Length Max
80 ft
Standard Line Set Length Vertical
50 ft
Standard Parts Warranty Commercial
ALL PARTS - 5 YEARS PARTS
Standard Parts Warranty Multifamily
ALL PARTS - 5 YEARS PARTS
Standard Parts Warranty Residential
ALL PARTS - 5 YEARS PARTS
Subcooling Temp At Service Valve
6 °F
Superheat Temp At Service Valve
8 °F
System High Pressure
450 lb/in²
System Low Pressure
240 lb/in²
Unit Depth
35-3/4 in
Unit Height
36-1/4 in
Unit Width
35-3/4 in
Us Hts Code
8415.90.8065
Valve Connection Type
Sweat
Valve Size Liquid Od
3/8 in
Valve Size Suction Od
3/4 in
Vertical Length Od Above Id
25 ft
Vertical Length Od Below Id
80 ft
Weight Unit
215 lb
Manufactured By
Goodman


Other Details:
  • 1. Heavy-gauge galvanized steel cabinet and louvered coil guards;2. Service valves with sweat connections and easy-access gauge ports;3. Engineered sound control top design;4. Wire fan discharge grille;5. Baked-on powder-paint finish with 500-hour salt-spr
  • 1. High-efficiency two-stage scroll compressor;2. High-efficiency two-speed ECM condenser fan motor;3. ComfortNet‚Ñ¢ Communications System compatible;4. Factory-installed filter drier;5. Factory-installed suction line accumulator;6. Factory-installed c
  • 1. The two-stage scroll compressor runs at either 65% or 100% capacity, depending on cooling/heating demand. This operational flexibility provides a great energy-efficient option when compared to a traditional, single-stage unit.;2. The top performance of
  • 16 SEER Two-Stage Heat Pump
Call for Price
Qty:
Add To Cart
Add To Estimate
Add To Wishlist
Save To Compare
Availability:
  • Manufacturer availability unavailable.
To: From: Subject:
Copyright 2020 XOLogic. ALL Rights Reserved. Privacy policy
Name
Company Name
Email
Phone Number
Industry - select all that apply*
Lighting
Electrical
Plumbing
Industrial
*Indicates required field
Name
Company Name
Email
Phone Number
Industry - select all that apply*
Lighting
Electrical
Plumbing
Industrial
*Indicates required field
Customer Copy
Images
Item Details
Customer Information
Item Prices
Order Totals
Vendor Information
Item Notes
Sales Rep Notes
Order Notes
Terms & Conditions
Pickup/Delivery Date
To: From: Subject:
Sort Items By
Images
Item Details
Customer Information
Item Prices
Order Totals
Vendor Information
Item Notes
Sales Rep Notes
Order Notes
Account Rebate
Terms & Conditions
Pickup/Delivery Date
Point of Sale